Edit the DSL on the left. Diagram re-renders on the right. Pick a preset below to start from a real example, or paste output from ChatGPT / Claude — the DSL is designed for LLMs to emit on the first try.

SLD·§ IEEE 315-1975
↘ preview
100%
Residential Consumer Unit — IEC 60364 Single-line diagram with 19 nodes and 18 connections Residential Consumer Unit — IEC 60364 230V 230V 1.5 mm² Cu PVC 2.5 mm² Cu PVC 2.5 mm² Cu PVC 4 mm² Cu PVC 4 mm² Cu PVC 6 mm² Cu XLPE 2.5 mm² Cu XLPE Service head 230V/63A 230V Wh kWh meter Main isolator 63A 6kA GFI Main RCD 63A / 30mA Type AC 230V · Consumer-unit busbar MCB lighting 6A B-curve MCB sockets ground floor 16A B-curve MCB sockets first floor 16A B-curve MCB kitchen ring 20A C-curve MCB water heater 20A C-curve GFI RCBO EV charger 32A / 30mA Type B MCB outdoor 10A B-curve Lighting circuit Sockets — ground floor Sockets — first floor Kitchen ring final Water heater 4.5 kW EV charger 7.4 kW Mode 3 Outdoor / garden
UTF-8 · LF · 38 lines · 1496 chars✓ parsed·12.4 ms·12.1 KB SVG